How to calculate injection molding press capacity
If an injection molding press is fully booked, the schedule alone cannot tell you whether you need more equipment. Start with a specific mold and press. Compare its ideal output with the good parts the cell produces during the time scheduled for that job. Then check whether any capacity you could recover is usable for the work you need to ship.
Calculate the design and running-cavity rates
Divide 3,600 seconds by the verified reference cycle time in seconds per shot. Multiply the result by the mold's designed cavities to get the design reference in parts per hour. Multiply by its currently running cavities to get the running-cavity reference.
A four-cavity mold at 30 seconds per shot has a design reference of 480 parts per hour. With one cavity blocked, the running-cavity reference is 360. This example assumes the same reference cycle for both configurations. If the cycle changes when the cavity is restored, use a separately validated cycle for that configuration. Use one row per part, mold, press and stable cavity configuration. Evaluate family molds by part number.
Estimate good output during scheduled production
Use one representative production window. Record scheduled production hours, actual run hours within that window, gross molded parts from the active cavities and first-pass good parts. Include startup rejects in the gross count when they were molded. Track changeovers and stops within the scheduled window as time losses. Count each stop or lost part once.
| Hypothetical inputs | Value |
|---|---|
| Designed cavities / active cavities | 4 / 3 |
| Reference cycle | 30 seconds per shot |
| Scheduled production / actual run time | 40 h / 34 h |
| Gross molded parts / first-pass good parts | 11,016 / 10,465 |
| Demand over the same window | 12,000 good parts |
Availability is 34 ÷ 40, or 85%. Running performance is gross parts ÷ (run hours × running-cavity reference), or 11,016 ÷ (34 × 360) = 90%. First-pass yield is good parts ÷ gross parts, or approximately 95%. Multiply the running-cavity reference by availability, running performance and yield. The result is approximately 262 good parts per scheduled hour, which equals 10,465 ÷ 40.
The 40-hour design reference is 19,200 parts. The 40-hour running-cavity reference is 14,400. Compared with the 10,465 actually produced, the 8,735-part design gap includes 4,800 parts of theoretical cavity loss. The remaining 3,935 parts reflect the time, speed and first-pass quality losses at the operating cavity count. Demand exceeds actual output by 1,535 good parts. The gap to design shows where to investigate. A recovery estimate requires a specific change and verified operating data.
Decide what capacity is usable before buying a press
Ask whether the load is limited by the press, the mold, material handling, labor, inspection, downstream operations, or scheduling. Study the jobs driving the shortfall. Verify press and mold fit before moving work, including clamp and shot capability, mold dimensions, auxiliary equipment, process validation, customer requirements and staffing. Confirm the candidate hours can serve the right jobs in time to meet demand. When jobs share a press, check their load in hours against one common schedule.
If running performance calculates above 100%, reconcile run hours, gross count, active cavities and the reference cycle before using the result. An unusually fast period can mean the reference is dated. If no parts ran, yield is unavailable and a fresh production window is needed for a rate estimate.
Use the sample first, then enter your own run data for one stable mold and press combination. If you're deciding whether to add a shift, fix a cavity, move jobs, or invest in equipment, the Manufacturing Readiness Assessment™ can help identify which constraint deserves attention first.
The Excel file has a blank worksheet and the hypothetical example above, worked step by step. To fill it in by hand, use the printable PDF on the Press Capacity Check page.
Schedule a Discovery ConversationFurther reading: OEE calculation and factor definitions (Vorne)